Hard X-rays for the study of fractures in bones should have a minimum wavelength of 10⁻¹¹ m. The accelerating voltage for electrons in X-ray machine should be
Options
(a) <124.2 kV
(b) >12.4 KV
(c) between 60 kV and 70 kV
(d) (=100 kV)
Correct Answer:
>12.4 KV
Explanation:
Minimum Wavelength λ = hc / eV = (1.242 × 10⁻⁶) / V
V = (1.242 × 10⁻⁶) / 10⁻¹¹ = 124.2 kV
The accelerating voltage for electron in X-ray is 124.2 kV
Related Questions: - There is a ring of radius r having linear charge densityλ and rotating with a uniform
- In a radioactive decay process, the negatively charged emitted β- particles are
- Maximum range for a projectile motion is given as R. The maximum height will be
- Vessel A is filled with hydrogen while vessel B, whose volume is
- A beam of light of wavelength 600 nm from a distant source falls
Topics: Dual Nature of Matter and Radiation
(150)
Subject: Physics
(2479)
Important MCQs Based on Medical Entrance Examinations To Improve Your NEET Score
- There is a ring of radius r having linear charge densityλ and rotating with a uniform
- In a radioactive decay process, the negatively charged emitted β- particles are
- Maximum range for a projectile motion is given as R. The maximum height will be
- Vessel A is filled with hydrogen while vessel B, whose volume is
- A beam of light of wavelength 600 nm from a distant source falls
Topics: Dual Nature of Matter and Radiation (150)
Subject: Physics (2479)
Important MCQs Based on Medical Entrance Examinations To Improve Your NEET Score
18000+ students are using NEETLab to improve their score. What about you?
Solve Previous Year MCQs, Mock Tests, Topicwise Practice Tests, Identify Weak Topics, Formula Flash cards and much more is available in NEETLab Android App to improve your NEET score.
Share this page with your friends

Leave a Reply